SEC 01 / DATASHEET

MK-7 electrical datasheet

Absolute maximum ratings, recommended operating conditions, DC characteristics, and switching timing for the BLW-MK7-40A.

REV 2.4UPDATED 2026-06-14
1.1

Absolute maximum ratings

Stresses beyond those listed may cause permanent damage. These are stress ratings only; functional operation is not implied. Exposure to maximum conditions for extended periods affects reliability.

RatingSymbolMinMax (unit)
Supply voltageVDD-0.33.9 V
Input voltage, any pinV_IN-0.3VDD+0.3 V
Sink/source per pinI_IO±40 mA
Storage temperatureT_STG-55150 ℃
ESD, HBMV_ESD2000 V
DANGER

Applying VDD above 3.9 V will destroy the internal LDO. Verify your regulator's overshoot at power-on before connecting the module.

1.2

Recommended operating conditions

ParameterSymbolMinTypMax (unit)
Supply voltageVDD3.03.33.6 V
Ambient temperatureT_A-402585 ℃
Input clockf_XTAL84048 MHz
1.3

DC characteristics

Unless otherwise noted, VDD = 3.3 V and T_A = 25 ℃. Register defaults can be read back over the debug UART with the command below.

readback.txt
$ blw reg read 0x40001008
IO_DRIVE = 0x0A # 8 mA, slew slow
VOH @ 8mA = 2.9 V (min 2.4 V)
VOL @ 8mA = 0.3 V (max 0.4 V)
ParameterSymbolConditionTyp (unit)
High-level outputV_OHI=8mA2.9 V
Low-level outputV_OLI=8mA0.3 V
Input leakageI_LKVin=VDD50 nA
Pull-up resistanceR_PUenabled45 kΩ
1.4

Switching timing

InterfaceSymbolMax (unit)
SPI clockf_SCK80 MHz
I²C fast-plusf_SCL1 MHz
UART baudBR5 Mbaud
1.5

Ordering information

Order codeFlashGradePackage
BLW-MK7-40A16 MBIndustrialLGA-56
BLW-MK7-40E8 MBExtendedLGA-56
BLW-MK7-DK16 MBDev kitCarrier
Blueline Works

Documentation for the Blueline MK-7 edge controller. Datasheets, pinouts, and revisions for people who solder as often as they type.

RESOURCES
  • SDK downloads
  • Reference boards
  • Errata bulletin
  • Community forum
DOC RELEASE NOTICE
© 2026 BLUELINE WORKS — DOC-BLW-MK7 REV 2.4
TERMS/PRIVACY/LICENSE
Dual7 template preview — this is a fictional demonstration business.
TemplateBlueline Works
Theme
Remix this siteExit